Picture of Burdick ELI 230 ECG (WAM)

Burdick ELI 230 ECG (WAM)


12-lead ECG with WAM

$1,942.00 (USD)
Product image Product image

The Burdick by Mortara ELI 230 ECG with the WAM wireless acquisition module delivers impressive 12-lead performance, while requiring minimal space.

Features 

Value without Compromise
The ELI 230 electrocardiograph provides complete functionality in a portable, compact device. Easy to use and feature rich, the ELI 230 offers a valuable solution with capabilities such as signal quality, accurate and reliable ECG interpretation, and full-size printouts.

High-Resolution Color LCD
High-resolution color display provides real-time preview of 12-lead ECG and post-acquisition review of acquired ECG.

Distinguished Mortara VERITAS Resting ECG Interpretation Algorithm
Widely recognized Mortara resting ECG interpretation algorithm uses gender and age specific criteria to provide a silent second opinion for resting ECG interpretation.

WAM wireless acquisition module
ELI 230 runs on the innovative WAM wireless acquisition module, which includes replaceable lead wires, lead fail indicator, and remote control with buttons for ECG acquisition and rhythm printing. The WAM wireless acquisition module is a unique wireless acquisition module that eliminates the need for a direct patient connection. Equivalent in size and weight to a conventional wired patient cable, the WAM provides freedom of movement for the clinician while acquiring electrocardiograms. ECG acquisition can be initiated at the WAM or the electrocardiograph. The WAM offers ON/OFF, 12-lead ECG acquisition, and rhythm printing at the bedside with a simple press of a button. Visual and audible feedback is provided at the WAM. The need to maneuver the electrocardiograph through the doorway to the patient’s bedside is eliminated; this is particularly advantageous in critical situations or when the patient is in isolation. Dedicated and secure communication links the WAM to a single electrocardiograph. Mortara wireless technology features full diagnostic-quality ECG with a high-fidelity acquisition sampling rate of 40,000 samples per second per channel, a benefit for accurate pacemaker detection. Elimination of the cable reduces a source of artifact resulting in high-quality ECG tracings. Under typical usage, the battery operated WAM can acquire 250 resting ECGs. Advanced power management automatically turns WAM off.

Best 10
ELI 230 automatically selects and displays the Best 10 seconds of ECG signal from the one-minute segment of internal full disclosure, reducing clinical review time and eliminating the need for repeat ECGs.

Diagnostic Quality
Mortara technology features full diagnostic ECG quality with a high-fidelity acquisition sampling rate of 40,000 samples per second per channel, a benefit for accurate pacemaker detection.

Technical Specifications

Instrument Type: 12-lead electrocardiograph
Input Channels: Simultaneous acquisition of all 12 leads
Standard Leads Acquired: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Waveform Display: Backlit, 1/4 VGA color LCD (320 x 240); 3, 4+4, or 6+6 lead presentation
Digital Sampling Rate: 40,000 s/sec/channel used for pacemaker spike detection; 1000 s/sec/channel used for recording and analysis
Resolutions: 1.875 microvolt LSB
A/D Conversion: 20 bits (1.17 microvolt LSB)
Frequency Response: 0.05 to 300 Hz
Filters: High-performance baseline filter; AC interference filter 50/60 Hz; low-pass filters 40 Hz, 150 Hz, or 300 Hz
Lead Reversal Section: Notification of possible lead reversal conditions, for both limb and chest leads, indicated on the display, prior to printing
Pacemaker Spike Detection: Pacemaker spike markers, for both atrial and ventricular rhythms, indicated on printouts
Optional Functions: Mortara VERITAS resting ECG interpretation with age and gender specific algorithm
Paper: Thermal roll paper; 210 mm (8.25”) wide
Thermal Printer: Computer-controlled dot array; 8 dots/mm
Thermal Printer Speeds: 5, 10, 25, or 50 mm/s
Gain Settings: 5, 10, or 20 mm/mV
Report Print Formats: Standard or Cabrera; 12, 6, or 3+1 channel
Rhythm Print Formats: 12, 6, or 3 channel with configurable lead groups
Device Classification: Class I, Type CF defibrillation-proof applied parts
ECG Storage: Internal storage up to 20 ECGs, external storage to USB memory stick
Connectivity: Review or print from ELI Link V4.xx
Weight: 5.8 lbs. (2.63 kg) including battery (without paper)
Dimensions: 11.25 x 7.5 x 2.75” (28.58 x 19 x 7 cm)
Power: Universal AC power supply (100-240 VAC at 50/60 Hz) 110 VA; internal rechargeable battery
 